Compressor motor restart problem

Craftsman 5 HP air compressor, model 919.167200

Compressor runs ok and switches off when set point is reached. Motor trips breaker when attempting a restart at lower pressure point. Evaluated check valve, unloader valve, and pressure switch, and all are functioning properly. Both the run and start caps are fine. Since the motor starts with no tank pressure the centrifugal switch for the caps appears to be working.

Any other possible issues to consider?

この質問に回答する 同じ問題があります

この質問は役に立ちましたか?

スコア 0

1件のコメント:

This question was migrated from https://meta.ifixit.com/Answers.

さんによる

コメントを追加