はじめに

If the battery on your Fluke 77 Series III Multimeter needs to be replaced, this guide details the steps for doing so. Replacing the battery is a routine, but critical part replacement for the Fluke 77 Series III Multimeter.

  1. Be sure any test leads are out and the multimeter is off before opening the device.
    • Be sure any test leads are out and the multimeter is off before opening the device.

    • Turn the multimeter so it is display side down.

    • Lift up the back stand of the device by putting your thumb in the curved well at the bottom of the device, so you have access to the two covered screws below.

    コメントを追加する

  2. Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.
    • Use your Phillips #2 Screwdriver to remove the four black 21 mm Phillips #2 screws.

    コメントを追加する

    • Turn the Fluke 77 Series III Multimeter back over so that it is display side up.

    • Pry the front panel from the back panel at the seam.

    • If the front panel does not come off easily, move a plastic opening tool along the seam until the panels separate completely.

    コメントを追加する

    • When doing this next step, make sure to remove the battery slowly, so you don't damage the wires connecting the battery to the device.

    • Locate the 9V battery in the lower right corner of the device.

    • Pull the battery out of its terminal.

    コメントを追加する

    • Only pull on the metal snaps and battery. Pulling the cords may damage them.

    • Detach the two metal snaps from the battery.

    コメントを追加する

まとめ

To reassemble your device, follow these instructions in reverse order.

4 の人々がこのガイドを完成させました。

Jessica Bombardier Shaw

メンバー登録日: 2014年01月29日

961 ポイント

7のガイドは作成済み

チーム

Cal Poly, Team 2-10, Amido Winter 2014 Cal Poly, Team 2-10, Amido Winter 2014人のメンバー

CPSU-AMIDO-W14S2G10

4 メンバー

10のガイドは作成済み

コメント1件

Easy to understand and all went well!

petruskewichw - 返信

コメントを追加する

統計データを表示:

過去 24時間: 10

過去 7 日: 52

過去 30 日: 162

今までの合計 6,687