OPERATION & SERVICE MANUAL
PORTABLE, SELF-CONTAINED VENTILATION SYSTEM (VENTILATOR, COMPRESSOR, AIRIOXYGEN MIXER)
UNI-VENTTM EagleTM 700 SERIES MODEL 754M
Impact Instrumentation, Inc 27 Fairfield Place West Caldwell, New Jersey 07006
1997 Impact Instrumentation, Inc PIN 906-0754-02
REV. 1.85 (02/98)
TA BL E 0 F C 0 NTENTS
| SUBJECT | PAGE |
|---|---|
| LIST OF ILLUSTRA TIONS | iv |
| CONVENTIONS, TERMINOLOGY, DEFINITIONS AND ABBREVIATIONS AS USED NN THIS MANUAL | vi |
| WORD ABOUT EAGLES | vii |
| SHIPPING CONTENTS | vii |
| ACCESSORIES LIST | vii |
| LIMITED COPYRIGHT RELEASE (MODEL 754M only) | viii |
| CALIBRATIONPPREVENTA TIVE MAINTENANCE NOTICE | viii |
| UNPACKING | viii |
| LOCATION OF USE | viii |
| WARNINGS AND CAUTIONS REGARDING USE | viii |
| ix | |
| SECTION I. OPERA TION | 1-] |
| INTRODUCTION | 1-1 |
| FEA TURES | 1-1 |
| DESCRIPTION OF CONTROLS, VISUAL NNDICATORS AND CONNECTIONS | 1-2 |
| CONTROLS | 1-2 |
| EXTERNAL AIR OFFION Switch SIGH OFFION Switch PEEP OFFION-set Switch PRESSURE PLA TEAU OFFION Switch HIGH PRESSURE ALARMPEAK INSPIRATORY PRESSURE RELIEF Control LOW PRESSURE ALARM Control VENTILATION RATE Control INSPIRA TION TIMEII:E RATIO Control TIDAL VOLUME Control AIRIOXYGEN MIXER Control ALARM MUTEICANCEL Switch MANUAL BREA THTRIGGER Switch MODE SELECTOR Switch | |
| LCD VISUAL NNDICATORS STATUS | 1-6 |
| MODE Vmin INSPIRA TIONEEXHALATION POWER INFORMATION CENTER PEAK AIRWAY PRESSURE MEAN AIRWAY PRESSURE DIGITAL BAR GRAPH HIGH and LOW AIRWAY PRESSURE ALARM SETPOINTS Paw EXTERNAL AIR SIGH PEEP PRESSURE PLATEAU . HIGH AIRWAY PRESSURE ALARM (setpoint) LOW AIRWAY PRESSURE ALARM (setpoint) RATE INSPIRA TION TIMEII:E RATIO TIDAL VOLUME FIOz |
Table Caption: This table is a table of contents for a manual, listing subjects and their corresponding page numbers, including sections on operation, controls, and visual indicators.
TABLE 0F C 0NTENTS, (cont'd)
| SUBJECT | PAGE |
|---|---|
| LED VISUAL INDICATORS | |
| STATUS CHARGE | 1-7 |
| ALARM | 1-8 |
| ALARM SYSTEM FAILURE | 1-8 1-8, 1-9 |
| LCD VISUAL NNDICATORS | |
| ALARMS - OPERATING BATTERY LOW EXTERNAL POWER LOW - LOW PRESSURE_ DISCONNECT HIGH PRESSURE APNEA HIGH PEEP _ 0z LOWIFAIL EXT AIR LOWFFAIL PRESSURE ALARM FIOz ~ | 1-8 |
| ALARMS - NON-OPERATING INVERSE I:E TRANSDUCER CALIBRATION ABORT - SYSTEM FAILURE VENTILATOR FAILURE | 1-9 |
| ALARMS ADVISORY NNSPIRATION TIME TRUNCATED TO 3-SEC _ PLATEAU VOLUME Vi SETTINGS PREVENTATIVE MAINTENANCE EXTENDED NON-USEISTORAGE EXTERNAL POWER FAILURE TOTAL FLOW BACKUP | 1-10 |
| CONNECTIONS OXYGEN INLET _ AIR NNLET GAS OUTLET TRANSDUCER _ EXHALATION VALVE EXTERNAL POWER JACK - COMMUNICATIONS PORT | 1-10 |
| OPERATING POWER SELECTION & STOPPING | 2-1 |
| INITIAL SET-UP, SELF-CHECK AND TRANSDUCER CALIBRATION | 3-1 |
| INITIAL SET-UP SELF-CHECK | 3-1 3-3 |
| TRANSDUCER CALIBRATION | |
| 3-3 | |
| AUTOMATIC CALIBRATION (AUTO CAL) MANUAL CALIBRATION | |
| USER PROGRAMS |
Table Caption: This table outlines the content and corresponding page numbers for a technical manual, covering topics such as visual indicators (LED and LCD), system operations like power selection and initial setup, connections, and user programs. It details various alarms, their page references, and specific calibration procedures.