メインコンテンツにスキップ

Marshall Monitor Headset Audio Cable Repair

フランス語
英語

ガイド情報

= 完了 = 不完全

      ガイドの手順

      手順1

      Examine the point at which the cable enters the housing to identify the location of the damaged part of the cable.

      手順2

      Remove the foam cushion and remove the 4 screws with a Torx screwdriver.

      手順3

      Unsolder the faulty cable connections.

      手順4

      Cut the cable upstream of the damaged area and remove 10mm of insulation.

      手順5

      Solder the 3 replacement wires and mark the corresponding color.

      手順6

      There is a good chance that the diameter of the replacement cable will be greater than the original. In that case it will be necessary to remove the original gold cable grommet (it is decorative anyway).

      手順7

      Reinsert the cable into the headset

      手順8

      Replace the foam inside the headset then gently reposition the upper part.

      クリエイティブコモンズのオープンソース著作権のもと、あなたの投稿は著作権の対象となります