手順2に変更
- BRIANによって編集
承認済みの編集 : Arthur Shi
- 前
- 後
- 変更なし
手順ライン
[title] Loosen the pump assembly | |
- | [* red] Use a |
+ | [* red] Use a 13mm socket to remove the four long bolts holding the pump assembly to the motor. |
[* icon_reminder] ***Re-assembly tip: ***The bolts hold the pump under pressure against the motor assembly. During reassembly, gradually tighten the bolts in a cross pattern. |