メインコンテンツにスキップ

Popular clothes dryer series by Kenmore.

60回答 すべてを表示

Can a blown Cutoff fuse keep my dryer from starting

Changed thermal fuse and fixed heater coil that was grounded. It blew the timer which I also fixed and have Continuity everywhere except the cutoff fuse. It still won’t start. Is this why are is it Control panel issues?

Update (09/29/2020)

Roper mod# red4640YQ1

回答がありました! 回答を表示 同じ問題があります

この質問は役に立ちましたか?

スコア 0
4 件のコメント

It’s an older Roper model

さんによる

I’ll get a better description if you need when I get off this afternoon

さんによる

Thank you I really appreciate it!!

さんによる

Update: the fuse was changed and dryer is running.... but now it just starts before pressing the start switch!!! Any suggestions?

さんによる

コメントを追加

1 件の回答

ベストアンサー

What exact model is this? We need to know that in order to try and look at the schematic and yes a bad cutoff can be the issue, but there may be more going on here.

Update (10/01/2020)

Ben Lewis, I can confirm that if the fuse is bad the dryer won't start or will run but not heat. So I would suggest to start with the fuse.

このアンサーは役に立ちましたか?

スコア 1

1件のコメント:

I posted in the old comments didn’t know if you would see it but the fuse worked but now when I put it on a cycle it just starts up before pressing start switch

さんによる

コメントを追加

回答を追加する

Ben Lewis さん、ありがとうございました!
統計データ:

過去 24時間: 0

過去 7 日: 0

過去 30 日: 3

今までの合計 102