メインコンテンツにスキップ

The fourth generation of Honda Accord covering model years 1990 through 1993 available in coupe, sedan, and wagon chassis.

46回答 すべてを表示

91 Honda Accord radiator fan.

Have a 91 Honda Accord that the radiator fan come on when you first crank the car and it stays on continuous while car is running and after car is off. If anyone has any info on this it would be much appreciated.

回答がありました! 回答を表示 同じ問題があります

この質問は役に立ちましたか?

スコア 0
1件のコメント

And if the relay is ok what would be the next place to look?

さんによる

コメントを追加

2件の回答

ベストアンサー

@adunlap21

check the temperature sensor which acts as a switch to turn the fan on at a certain temperature. It is possible that it has failed and stays closed. You did not tell us the exact model or engine size of your Honda so you will have to check for the location of the sensor. It is usually located by the thermostat housing. Follow the top host going to the engine block to find it. Once found you can simply check the sensor with a multimeter set on resistance.

このアンサーは役に立ちましたか?

スコア 2

2 件のコメント:

The temperature sensor on car is new that is what leaves me puzzled. It’s a 91 Honda Accord with a 2.2 engine.

さんによる

In that case the next suspect would be the fan relay

さんによる

コメントを追加

Hi @ mrsmith271983

There is a fan timer way up under the dash that goes bad often on these cars.

Block Image

(click on image to enlarge for better viewing)

このアンサーは役に立ちましたか?

スコア 1
コメントを追加

回答を追加する

Archie dunlap さん、ありがとうございました!
統計データ:

過去 24時間: 3

過去 7 日: 7

過去 30 日: 22

今までの合計 2,064