メインコンテンツにスキップ

Repair guides and support for home heating, ventilation, and air conditioning system repair.

346回答 すべてを表示

Amanda ac and heating system is showing br

Hi my Amanda ac and heating system is showing br when I tried to turn on my ac can anyone help me fixing my ac problem I tried the test it was working good but later on it shows the same code br

回答がありました! 回答を表示 同じ問題があります

この質問は役に立ちましたか?

スコア 2
5 件のコメント

sunjaibomma what model Amana is your AC? what have you tried so far to fix it? Where are you located and how is the regional power grid? Any chance that you are having local power issues?

さんによる

I get four lines instead of two when I am trying to program the unit and it does not let me go any further all i can scroll is 00 to 99?

さんによる

Okay I am at my job at a hotel ans I have a few ptac units that are hooked to thermostat and all of a sudden go into code BR ive resetted unit and still does the same exact thing. Model is pth094g35axxxaa.

さんによる

I have two Amana ptc123g50's. I was sweeping the kids room and accidentally ran over the thermostat wire that plugs in below the display panel. It read "F1" immediately and will not reset or turn back on! HELP PLEASE

さんによる

So I have tried to reset my unit that has code BR.. I have checked voltage and changed braker and outlet and still say BR.. tried doing reset by holding down hot and cold at same time.. is there any other

さんによる

コメントを追加

2件の回答

ベストアンサー

sunjaibomma Amana AC common error codes

CODE = br

FAILURES STATUS = Brown Out Protection engaged. Power was lost or voltage is low.

DISPLAY = N

ERROR LIGHT = N

SUGGESTED ACTION = Check for incoming power at correct voltage.

Let us know what model your Amana is so that we can double check this.

このアンサーは役に立ちましたか?

スコア 4

5 件のコメント:

Model #FTC123B35AMNP

さんによる

PTC123E35AXXXAB

Help me out with resetting mine. Mine is showing Br also.

さんによる

Tried reset but not working

さんによる

PTH153G50AXXXCA same problem.... Showing br code.

さんによる

fishagua so what did you check?

さんによる

コメントを追加

Just unplug, wait 5 seconds, hold the heat and cool buttons down at the same time (not the plus and minus ones), plug unit back in while continuing to hold heat and cool buttons down, wait till red light appears next to off button. Done. This will clear the BR and reset unit back to factory defaults.

このアンサーは役に立ちましたか?

スコア 2

5 件のコメント:

Thanks very much for this information.

さんによる

Unplugging and holding those 2 buttons doesn't even

さんによる

Tried that method 4 times,. Still goes back to br code..

さんによる

Model pth094g35axxxaa

さんによる

Check your circuit breaker if it's winter remove the thermostat and then put it back in if it's summer probably low on freon or dirty coils filters bower etc

さんによる

コメントを追加

回答を追加する

sunjaibomma さん、ありがとうございました!
統計データ:

過去 24時間: 2

過去 7 日: 25

過去 30 日: 89

今までの合計 22,544