How to remove and replace the motor for bObi's main brushes.

Remove bObi's dustbin. Press the small latch on the back and it will pop out.
  • Remove bObi's dustbin. Press the small latch on the back and it will pop out.

  • Uninstall the 2 screws close to bObi’s dustbin, plus 2 smaller screws above the main brushes.

コメントを追加する

To detach the brushes completely, unplug them from bObi.
  • To detach the brushes completely, unplug them from bObi.

  • The motor is on the bottom of the main brush attachment. Uninstall the four screws which secure it, then lift the motor out.

  • Remove the stabilizer attached to the motor’s end, closer to its circuit plug before pulling the whole piece out.

コメントを追加する

  • Slide the long metal end in first, through the second stabilizer, so the end fits inside the motor holder.

  • Place the stabilizer you removed previously on the new motor.

Without a replacement, how can I diagnose the problem with motor and how can I correct it?

chesterdh - 返信

alternatively, what is number/source of replacement motor of right kind?

chesterdh - 返信

  • Align the stabilizer with the screw posts on the brush holder, then install all four screws.

  • Connect the motor’s circuit plug.

  • Place the main brush attachment in bObi so it sits flat.

  • Line up the red fastener on bObi, and replace its two smaller screws.

コメントを追加する

  • Lay the two screw holders down. Then install each screw.

  • Slide bObi's dustbin back in until it locks in place.

コメントを追加する

まとめ

To reassemble your device, follow these instructions in reverse order.