はじめに

A damaged hose will not allow the vacuum to function properly. This guide will assist in the replacement process. The hose is electrically attached to the other components of the vacuum. Removal of the hose will require electrical components.

  1. Press down on the hose release button  and pull away from the vacuum
    • Press down on the hose release button and pull away from the vacuum

    コメントを追加する

  2. Press down on the wand release button and remove the  wand from the vacuum.
    • Press down on the wand release button and remove the wand from the vacuum.

    コメントを追加する

    • Press down on the handle release button and pull the wand away from the vacuum.

    コメントを追加する

    • Remove five 13.4 mm screws from the handle with a T20 Torx bit.

    コメントを追加する

    • Using a T20 Torx bit, remove the two 13.4 mm screws from the front of the nozzle.

    5.1) Remove collar on the bottom of the handle. A heat gun may be needed to release the tabs if the will not realease on thier own.

    5.2) Remove both sides of the green cover, starting with the side where you removed the screws, use the spuder to get the sidees apart. There are tabs all the way around and will require some force to get apart. Remove the screw holding the grey handle, under the green tab. The grey textureized grip will come off, along with the sliding tab, when the cover is removed.

    Mary Hambly - 返信

    • Remove the neck ring by placing a spudger under the brace and lifting outwards.

    • It may be helpful to use a heat gun on the brace and then attempt removing with a spudger.

    コメントを追加する

    • Run the spudger along the center seam of the handle, pulling it apart as you go.

    コメントを追加する

    • Remove the single 13.4 mm screw at the bottom of the handle grip and then lift the grip with a spudger.

    コメントを追加する

    • Remove the single 13.4 mm screw from underneath the handle grip. You are then able to open the handle using a spudger and pulling the pieces apart.

    コメントを追加する

    • Using two spudgers, unclip the hose from the handle.

    コメントを追加する

    • Use wire cutters to clip the white and black wire that connect the hose to the handle.

    • Soldering or wire connectors are necessary for reassembly.

    • Any time you are dealing with electrical components, be sure the device is unplugged.

    One white, and one black wire

    Mary Hambly - 返信

まとめ

To reassemble your device, follow these instructions in reverse order.