  1. Nikon D90 Rear Case Replacement, Rear Case: 手順 1、 2の画像 1 Nikon D90 Rear Case Replacement, Rear Case: 手順 1、 2の画像 2
    • Slide the eyepiece up and off the viewfinder.

  2. Nikon D90 Rear Case Replacement: 手順 2、 1の画像 1
    • Using a PH000 screwdriver, remove the two 4.8mm Phillips screws from the back of the viewfinder.

    • Some screws may be JIS. Be wary of this if your PH000 does not feel like it is properly gripping the screws.

  3. Nikon D90 Rear Case Replacement: 手順 3、 1の画像 1
    • Remove the two 6.4mm Phillips screws on the right side of the camera, near the SD card slot.

  4. Nikon D90 Rear Case Replacement: 手順 4、 1の画像 1
    • Remove the two 6.4mm Phillips screws on the left side of the camera, near the I/O ports.

  5. Nikon D90 Rear Case Replacement: 手順 5、 1の画像 1
    • On the bottom of the camera,

    • remove the two 5.3mm Phillips screws

    • and the other two 6.3mm Phillips screws.

  6. Nikon D90 Rear Case Replacement: 手順 6、 3の画像 1 Nikon D90 Rear Case Replacement: 手順 6、 3の画像 2 Nikon D90 Rear Case Replacement: 手順 6、 3の画像 3
    • Using a spudger, separate the bottom panel from the rear case just enough to clear the two clips on the rear casing in the next step.

  7. Nikon D90 Rear Case Replacement: 手順 7、 2の画像 1 Nikon D90 Rear Case Replacement: 手順 7、 2の画像 2
    • Lift the rear case off of the back of the camera.

    • Don't pull the casing completely off yet, as the ribbon cables are still connected.

    • Be mindful of the two clips, making sure to keep the bottom panel far enough away to clear them.

  8. Nikon D90 Rear Case Replacement: 手順 8、 1の画像 1
    • Set the rear casing off to the side so you can access the ZIF connectors.

    • The orientation shown in the picture seems to be the best position for the casing to sit comfortably without stressing the ribbon cable connections.

  9. Nikon D90 Rear Case Replacement: 手順 9、 3の画像 1 Nikon D90 Rear Case Replacement: 手順 9、 3の画像 2 Nikon D90 Rear Case Replacement: 手順 9、 3の画像 3
    • Use a spudger to lift the black tab on the ZIF connector.

    • Disconnect the ribbon cables from their respective ZIF connectors on the logic board.

  10. Nikon D90 Rear Case Replacement: 手順 10、 1の画像 1
    • Separate the rear casing from the camera.

終わりに

To reassemble your device, follow these instructions in reverse order.

8 の人々がこのガイドを完成させました。

作成者

7人の作成者と共同で作成されました。

Ryan Lutz

メンバー登録日: 09/27/11

3,008 ポイント

3のガイドは作成済み

2 件のコメント

good guidance,easy to follow,thanks

ramalingeswarao kaza - 返信

I want to replace my Nikon D90 DSLR bad LCD, this guide will save me from costly repairs.

ramalingeswarao kaza - 返信

コメントを追加

統計データ:

過去 24時間: 1

過去 7 日: 4

過去 30 日: 17

今までの合計 4,198