  1. Holmes HEH8031 Safety Weight Replacement, Housing: 手順 1、 1の画像 1
    • Ensure the device is unplugged from the wall outlet.

  2. Holmes HEH8031 Safety Weight Replacement: 手順 2、 1の画像 1
    • Remove eight 12-mm Phillips #2 screws from the back cover.

  3. Holmes HEH8031 Safety Weight Replacement: 手順 3、 2の画像 1 Holmes HEH8031 Safety Weight Replacement: 手順 3、 2の画像 2
    • Turn heater over so the controls are facing up.

    • Lift the front housing away from the back of the fan and slowly fold the front housing back down to the floor.

    • Internal wires are connected to both halves of the housing. Be careful when separating the housing.

  4. Holmes HEH8031 Safety Weight Replacement, Circuit Board Removal: 手順 4、 1の画像 1
    • Remove four 12mm Phillips #2 screws from the circuit board.

  5. Holmes HEH8031 Safety Weight Replacement, Safety Weight: 手順 5、 2の画像 1 Holmes HEH8031 Safety Weight Replacement, Safety Weight: 手順 5、 2の画像 2
    • Remove wires from safety weight, as shown.

    • Pull upward on the blue connectors.

    • If connectors are tough to remove, try wiggling while pulling upward.

  6. Holmes HEH8031 Safety Weight Replacement: 手順 6、 1の画像 1
    • Unscrew the Phillips #2 10 mm screw from the safety weight on the rear housing panel.

終わりに

To reassemble your device, follow these instructions in reverse order.