Health o Meter HDR743 Power Supply Replacement

必要な工具と部品

  1. Health o Meter HDR743  Power Supply Replacement, Power Supply: 手順 1、 1の画像 1
    • Connect a voltmeter at the power supply’s connection to the circuit board and the power supply.

    • If the the voltage at the power supply is incorrect, the power supply should be replaced.

  2. Health o Meter HDR743  Power Supply Replacement: 手順 2、 1の画像 1
    • Use wire strippers to cut the wired connection to the power supply.

    • If the wires need replacing, you will need to use a soldering iron and remove the connections at the board.

  3. Health o Meter HDR743  Power Supply Replacement: 手順 3、 1の画像 1
    • Use the wire strippers to cut off the rubber ends of the power supply wires.

    • Use a soldering iron and solder to fuse the connections between the two wires.

  4. Health o Meter HDR743  Power Supply Replacement: 手順 4、 2の画像 1 Health o Meter HDR743  Power Supply Replacement: 手順 4、 2の画像 2
    • Test the power supply once the wires have been reconnected.

    • If the Health o Meter still has power issues, check the connections between the new power supply and the board.

    • If no issues are found, the circuit board may need to be replaced.

終わりに

To reassemble your device, follow these instructions in reverse order.