1. Unplug the device from any energy sources.
    • Unplug the device from any energy sources.

    • Lift the top cover of the scanner.

    • Use a plastic opening tool to remove the plastic frame surrounding the glass.

    コメントを追加する

  2. Carefully pull the frame away from the glass.
    • Carefully pull the frame away from the glass.

    • If it doesn't remove easily, use the iFixit Opening Tool again to pry stuck sections.

    コメントを追加する

    • Use a T10 screwdriver to unscrew the two screws that fasten the frame to the printer hood.

    コメントを追加する

    • Put your finger behind the panel with the power button.

    • Then, pull the piece outwards.

    コメントを追加する

  3. Fixmasのスピリットを広めましょう
    クーポンコードFIXMAS12を使えば、50ドル以上のお買い上げで12ドル割引となります。
    Fixmasのスピリットを広めましょう
    クーポンコードFIXMAS12を使えば、50ドル以上のお買い上げで12ドル割引となります。
    • Unscrew the screw inside the power button panel space.

      • Then, unscrew the screw that is across the printer slider.

    コメントを追加する

    • Pull the white circuit board outwards which is located under the small screen.

    • Unplug the small ribbon cable from the circuit board.

    • Be careful when you unplug the ribbon cable not to use too much force. Using too much force may damage or rip the cable.

    コメントを追加する

    • Unplug the small ribbon cable from the circuit board. Be careful when you unplug the ribbon cable not to use too much force. Using too much force may damage or rip the cable.

    コメントを追加する

    • Pull the memory card reader's circuit board out.

    • Detach the white wiring connector from the back of the circuit board.

    • You may need to use a finger nail or a plastic opening tool to detach the white wiring connector from the circuit board.

    コメントを追加する

    • Put your finger behind the small screen.

    • Then, pull it up.

    • Do not hesitate to use force to remove the TouchSmart panel.

    • Disconnect the ribbon cable from the small screen.

    コメントを追加する

    • Pull the printer hood upward.

    コメントを追加する

    • Lift the scanning lid from the lower portion of the printer hood.

    Remove torx screw on bottom of assembly in corner near touchsmart screen space.

    Jeff - 返信

    • Leaving the ribbon connected, lift the sliding scanner off the track.

    • Pull the ribbon cable out of the slot on the scanner circuit board.

    • Insert the scanning piece into the rolling track.

    コメントを追加する

まとめ

To reassemble the sliding scan piece, follow these instructions in reverse order.

Renee Lamb

メンバー登録日: 2012年09月26日

226 ポイント

3のガイドは作成済み

チーム

Cal Poly, Team 2-11, Propen Fall 2012 Cal Poly, Team 2-11, Propen Fall 2012人のメンバー

CPSU-PROPEN-F12S2G11

4 メンバー

6のガイドは作成済み

コメント1件

Where can i buy the scaning piece? Im from Spain.

Bogdan Cosmin - 返信

コメントを追加する

統計データを表示:

過去 24時間: 0

過去 7 日: 1

過去 30 日: 8

今までの合計 1,241