メインコンテンツにスキップ

Epson Stylus NX230 Motor Replacement

必要な工具と部品

  1. Epson Stylus NX230 Motor Replacement, Motherboard: 手順 1、 1の画像 1
    • Check to make sure the printer is unplugged to prevent electric shock.

  2. Epson Stylus NX230 Motor Replacement: 手順 2、 2の画像 1 Epson Stylus NX230 Motor Replacement: 手順 2、 2の画像 2
    • Align your printer so that the front buttons face to the right.

    • Remove the 3mm Phillips #2 screw in the hole in the top left corner. This screw attaches the side panel to the printer.

    • Store the screws in a safe place so you can access them later.

  3. Epson Stylus NX230 Motor Replacement: 手順 3、 1の画像 1
    • Flip and remove the top of the printer up so that you can see the inside.

    • There is a white strip in the top right corner of the printer called the ribbon cable.

    • Make sure that the ribbon cable does not detach from the printer to prevent damaging the connection.

  4. Epson Stylus NX230 Motor Replacement: 手順 4、 2の画像 1 Epson Stylus NX230 Motor Replacement: 手順 4、 2の画像 2
    • Align the printer so the front button panel faces to the right.

    • Remove the 3mm Phillips #2 screw on the side of the printer in the top left corner.

    • Store the screw in a safe place so you can access it later.

  5. Epson Stylus NX230 Motor Replacement: 手順 5、 2の画像 1 Epson Stylus NX230 Motor Replacement: 手順 5、 2の画像 2
    • Take the right side of the bar of plastic that runs across the top of the inside of the printer and push it towards the left side of the printer.

    • Take the left side of the bar and push it to the left and then to the right.

  6. Epson Stylus NX230 Motor Replacement: 手順 6、 3の画像 1 Epson Stylus NX230 Motor Replacement: 手順 6、 3の画像 2 Epson Stylus NX230 Motor Replacement: 手順 6、 3の画像 3
    • Using your hands, detach the side panel from the printer.

    • Take extra care with the locking mechanisms, which help keep the side panel on the printer.

    • You may need to use the plastic opening tools to pry apart the locking mechanisms.

  7. Epson Stylus NX230 Motor Replacement: 手順 7、 1の画像 1
    • Remove the two 3mm Phillips #2 screws attaching motherboard to the printer.

    • Store the screws in a safe place so you can access them later.

    • The motherboard can now be removed from the printer.

  8. Epson Stylus NX230 Motor Replacement, Motor: 手順 8、 1の画像 1
    • Remove the four 3mm Phillips #2 screws attaching the motor to the printer.

    • Store the screws in a safe place so you can access them later.

  9. Epson Stylus NX230 Motor Replacement: 手順 9、 1の画像 1
    • Place the printer on it's side so that the motherboard's location is facing up.

    • Push the motor up and out of the hole that it is in.

    • The motor will slide out of the hole at the top after that.

終わりに

To reassemble your device, follow these instructions in reverse order.