    • Power down the unit by pressing the power button until the display goes black.

    • This is usually about 3 seconds.

    • Unplug the power cord from the wall outlet.

  2. CyberPower UPS Battery Replacement: 手順 2、 3の画像 1 CyberPower UPS Battery Replacement: 手順 2、 3の画像 2 CyberPower UPS Battery Replacement: 手順 2、 3の画像 3
    • Remove the battery plate cover at the bottom of the UPS using a Phillips #1 screwdriver.

    • If the screwdriver is not magnetized, tap on the cover plate to completely remove the screw.

  3. CyberPower UPS Battery Replacement: 手順 3、 2の画像 1 CyberPower UPS Battery Replacement: 手順 3、 2の画像 2
    • Slide the battery cover plate to the left.

    • Grasp the battery plate cover and lift it off the the UPS.

  4. CyberPower UPS Battery Replacement: 手順 4、 3の画像 1 CyberPower UPS Battery Replacement: 手順 4、 3の画像 2 CyberPower UPS Battery Replacement: 手順 4、 3の画像 3
    • Pull out the battery to expose the terminal connectors.

    • Use needlenose pliers to disconnect both battery terminal connectors.

    • Do not pull the connectors by the wires, pull connectors by grabbing the connector itself.

    • With the battery terminal connectors disconnected, slide the battery all the way out.

  5. CyberPower UPS Battery Replacement: 手順 5、 3の画像 1 CyberPower UPS Battery Replacement: 手順 5、 3の画像 2 CyberPower UPS Battery Replacement: 手順 5、 3の画像 3
    • The replacement battery should be a 12 volt, 9 amp-hour, sealed lead acid battery with f2 type connectors.

    • Install the new battery and reconnect the terminals.

  6. CyberPower UPS Battery Replacement: 手順 6、 3の画像 1 CyberPower UPS Battery Replacement: 手順 6、 3の画像 2 CyberPower UPS Battery Replacement: 手順 6、 3の画像 3
    • Slide the battery cover plate to the left.

    • Insert the screw to secure the battery cover plate.

    • Tighten the screw with a Phillips #1 screwdriver.

  7. CyberPower UPS Battery Replacement: 手順 7、 3の画像 1 CyberPower UPS Battery Replacement: 手順 7、 3の画像 2 CyberPower UPS Battery Replacement: 手順 7、 3の画像 3
    • Plug system into the wall outlet.

    • Press the power button to turn on the unit.

終わりに

To reassemble your device, follow these instructions in reverse order.

ある他の人がこのガイドを完成しました。

作成者

2人の作成者と共同で作成されました。

Jervon Stuart

メンバー登録日: 10/07/20

169 ポイント

1ガイドが承認済み

チーム

University of Memphis, Team S3-G8, Willis Fall 2020 University of Memphis, Team S3-G8, Willis Fall 2020人のメンバー

UM-WILLIS-F20S3G8

1 メンバー

2のガイドは作成済み

0 件のコメント

コメントを追加

統計データ:

過去 24時間: 12

過去 7 日: 79

過去 30 日: 311

今までの合計 12,548