はじめに
If you have this error and the voltage at the battery port is normal so you have to check C1055 with diode mode it should give you low values like 0.002V, remove the capacitor and measure again the pads where capacitor used to be if the value don’t change then remove the U1002 IC and replace with a new one.
必要な工具と部品
もう少しです!
To reassemble your device, follow these instructions in reverse order.
終わりに
To reassemble your device, follow these instructions in reverse order.
4 の人々がこのガイドを完成させました。