Using schematic diagram and wires how can I figure out why washer can'

Friddgedair combo used- washer wont run after water level fill sensor reached unless dryer start button pushed. How to check wiring for washer to run separately from dryerFriddgedair combo used- washer wont run after water level fill sensor reached unless dryer start button pushed. How to check wiring for washer to run separately from dryer

この質問に回答する 同じ問題があります

この質問は役に立ちましたか?

スコア 0

3 件のコメント:

Hi,

What is the model number of the combo unit?

Has it worked OK for you before?

さんによる

Fridgedair flxe52rbs8

さんによる

According to person bought from yes. Only change I made was switching 4 prong cord to 3 prong for our current outlet.

さんによる

コメントを追加

1 件の回答

Hi @April Taylor

Just confirming that the 3 prong wall outlet is a 240 V AC supply installed for the combo unit i.e. 2 x 120V active wires, each supply separately fused in the power box and a Neutral wire and not that it is the standard household 3 prong outlet of 1 x 120V active, 1 x Neutral and 1 x earth

Note: At least one of the 120V power supplies to the wall outlet needs its own fuse. The other 120V supply can be connected to the same fuse as the other wall outlets in that area of the premises

Here's the user manual that describes the electrical connections - see p.7 that may help.

このアンサーは役に立ちましたか?

スコア 0

2 件のコメント:

Yes. We have lived here for 16 yrs and have had front load sets as well as another fridgedair unit with no issues such as this one.

さんによる

@April Taylor

OK, but did those units require 120V AC or 240V AC to work? The combo unit requires 240V AC

You need to check that there is 240V AC between the 2 Active pins of the wall outlet socket that the combo unit is connected to

If there is 240V AC between the 2 Active pins then check that there is 120V AC between each Active pin and the Neutral pin in the socket. This is to make sure that the Neutral wire is OK

If there is no 240V then do the 2nd test above to check which 120V AC supply is missing.

Be safety aware: If you don't know how to test potentially lethal AC voltage safely, then don't do it! Call an electrician

さんによる

コメントを追加

回答を追加する