テキスト:

You are probably missing FL11, aka FL2400 in the SE —and definitely missing two of the caps. The picture is clear for the two caps, and less clear at FL2400.[br]

[br]

If the symptoms that this phone are having are a match for missing gas gauge filter, then you know that FL2400 is not on the board.[br]

[br]

Gas gauge problems in SE:[br]

With a charged battery phone will reboot every 3 minutes

Battery percentage reported wrong—will say 1% or 100% or jump up and down erratically[br]

[br]

3utools software does not “see” the battery percentage in battery details.[br]

[br]

With a dead battery, the low battery “plug me in” logic will not engage, the phone will try to boot instead and show apple logo then loop.[br]

[br]

usb ammeter will show low charging current, less than 0.5A[br]

[br]

If those are the symptoms, then yes—-send this phone out for SE “little peckers replacement”[br]

I see that you contacted me on iPad Rehab Microsoldering website, but I’m answering here to help anyone else with a similar problem in the future figure out if they have a little pecker problem ;0[br]

[br]

Jessa